Outcomes in Patients with Proximal Humerus Fractures Undergoing Open Reduction and Internal Fixation with Proximal Humerus Locking Plate
DOI:
https://doi.org/10.59058/jaimc.2023.21.1.160Keywords:
Proximal Humerus fracture, Proximal Humeral locking plate, screw penetration, osteoprotic bone.Abstract
Background & Objective: Despite of conservative management for proximal humeral fractures, open
reduction and internal fixation with proximal humeral locking plate has become the most frequent treatment
for these fractures especially in elderly and osteoporotic population. A lot of complications are associated with
proximal humerus internal locking system (PHILOS) plate including intra articular screw penetration, screw
cut out, varus malunion, loss of reduction, nonunion and infections. Efforts have been made to improve the
locking plate fixation technique and strengthen the fixation more resilient to head collapse, screws cut out,
screw penetration and loss of fracture reduction.
Methods: It was an observational study conducted in the Department of orthopaedic surgery, Services
Hospital Lahore. About 30 patients having isolated proximal Humerus fracture with age between 40-75 years
being treated with promixal humral locking plate were included in the study after permission from ethical
review board. Patient with head, spine, abdomen and chest injury or poly trauma were excluded. There were
Eight with 2 – part, 15 with 3- part fractures and 7 with 4- part fractures. All these patients were followed at
interval of 3 weeks, 6 weeks, 3 months, 6 months and at one year.
Results: In all our 30 patients, fracture united 3 months after the surgery. In 05 patients there were screw
penetration in the shoulder joint. In these 05 patients, 03 patients developed avascular necrosis (A VN) and
underwent shoulder arthroplasty. Loss of reduction was present in 04 patients in whom the revision surgery
was done with addition of bone graft. Range of movements were significantly less in patients with 4- part
fracture( forward elevation was 95 degree and head shaft angle was 100 degree in these patients while
external rotation was 22 to 30, in rest of 35 patients it was within the normal range. Mean DASH score
(Disabilities of Arm, Shoulder and Hand) after 6 weeks was 3.2 – 58.4 while after one year at the end of final
follow up it was 13.3 – 48.6.
Conclusion: Our results reveal that PHILOS fixation technique is an acceptable stabilization procedure for
proximal humeral fractures. One must be aware of potential hardware complications. For unstable proximal
humerus fractures locking plates is a reasonable option especially in 3- part and 4- part fractures in osteoprotic
bone. But at the same time it has got high complication rate like screw penetration in the joint, loss of fracture
reduction and varus malunion etc.
Downloads
Downloads
Published
Issue
Section
License
Copyright (c) 2023 Muhammad Zafar Iqbal Shahid, Sohaib Inaam Ullah, Muhammad Khalid, Naveed Ali Shair, Tahir Mahmood, Muhammad Iqbal (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.